BIXOLON SRP-350IIOBE Specifications Page 90

  • Download
  • Add to my manuals
  • Print
  • Page
    / 133
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 89
SRP-350IIOBE
Rev. 1.00 BIXOLON
- 90 -
<Function 080> GS ( k pL pH cn fn m d1...dk (fn=80)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
d1...dk
Hex
1D
28
6B
pL
pH
30
50
30
d1...dk
Decimal
29
40
107
pL
pH
48
80
48
d1...dk
Range:
4 ≤ (pL + pH x 256) ≤ 65535 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 255)
cn=48
fn=80
m=48
0 ≤ d ≤ 255
k = (pL + pH x 256) 3
Default:
None
Description:
This command stores the PDF417 symbol data (d1...dk) in the symbol storage area.
Remarks:
The data stored in the symbol storage area by this command remains reserved after processing Function 081 or 082.
The following data should not be included in the symbol data d1..dk since this information is automatically added by
the printer:
Start pattern and stop pattern.
Indicator codeword of left and right.
The descriptor of symbol length (the first code word in the data area).
The error correction codeword calculated by modulus 929.
The setting of this command remains effective until the following processing is performed:
Executing Function 080
Executing ESC @
Executing printer reset or power-off
Differences:
None