BIXOLON SRP-350IIOBE Specifications Page 69

  • Download
  • Add to my manuals
  • Print
  • Page
    / 133
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 68
SRP-350IIOBE
Rev. 1.00 BIXOLON
- 69 -
<Function 48> GS ( L pL pH m fn (fn=0, 48)
Code:
ASCII
GS
(
L
pL
pH
m
fn
Hex
1D
28
4C
pL
pH
m
fn
Decimal
29
40
76
pL
pH
m
fn
Range:
(pL + pH x 256) = 1 (pL=2, pH=0)
m=48
fn=0, 48
Default:
None
Description:
Tramsmits the total capacityu of the NV bit-image momory (number of bytes in the memory area).
Remarks:
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Identifier
21H
33
1 byte
Setting value
30H or 31H
48 or 49
8 bytes
NUL
00H
0
1 byte
The total capacity data is converted to character codes corresponding to decial data, then transmitted from the MSB.
The data length is variable.
The total capacitu of the NV user memory is selectable as any one of[0, 64K, 128K, 192K, 256K] bytes with GS ( E.
The default value is 256K.
Differences:
None