SRP-350IIOBE
Rev. 1.00 BIXOLON
- 84 -
<Function 065> GS ( k pL pH cn fn n (fn=65)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
41
n
Decimal
29
40
107
3
0
48
65
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48, fn=65
0 ≤ n ≤ 30
Default:
n = 0
Description:
This command specifies the number of columns in the data area of PDF417.
When n=0, automatic processing is set
When n is not 0, the number of columns of the data area is set to n code word.
Remarks:
Settings of this command affect the processing of Functions 081 and 082.
With auto processing (n=0) specified, the maximum number of columns in the data area is set to 30 columns.
The following data is excluded from the number of columns:
Start and stop patterns
Indicator code word of left and right
With auto processing (n=0) specified, the number of columns is calculated using the following information.
Printing area when processing Functions 081, 082
Module width (Function 067)
Option setting (Function 070)
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None
Page view 83